Data Center

Introduction to 100G QSFP28 Bidirectional Transceivers

TARLUZ 100G QSFP28 Bidirectional transceivers are a cost saving solution for building a network or upgrading an existing network, the transceivers provide 100G connectivity for platforms at up to 80km on single SMF (Single Mode Fiber). Features Full-duplex 100Gb at up to 80km on single SMF Saves optical fiber Works in QSFP28 ports Operate in […]

Data Center

Which MPO connector should I use?

The three most common MPO connector options are MPO-8, MPO-12, MPO-24 and MPO-16. MPO-8 is a legacy standard for the QSFPs, coming out of the transceivers running 40 Gigabit or 100 Gigabits. It is used for both multimode and singlemode transceivers and breakouts, but offers the lowest density option, because you’ll have to have more […]

AI, Data Center

Will TMT Ferrule Technology be an idea choice for AI Data Center?

The TMT ferrule format is based on the proven alignment structure of MT and MT-16 ferrules used in MPO and MPO-16 applications. Engineered for durability, the novel shoulder features ensure precision polishing combined with the mechanical integrity needed for repeated insertion and extraction cycles. In addition to MMC applications, TMT ferrules are ideal for on-board […]

AI, Data Center

Introduction to Cable Jacket used for AI Data Center

The fiber is fragile and easy to break, the cable jacket is a good measure to protect the fiber been damaged. The cable structure includes buffers, strength members, and jackets. The following articles offer a brief introduction to the cable jacket used inside the data center. LSZH LSZH (low-smoke, zero halogen) jacket is free of […]

AI, Data Center

Base-16 Fiber Cabling Introduction

2028. While the 800G and 1.6T pluggable now are mainly based on 16 fiber, in the article, we shall briefly introduce the Base-16 Fiber Cabling System. 1. What is Base-16 Fiber? Base-16 fiber mainly means 16x fiber cores in a tube and can be single or ribbonized. it can be terminated by high-density MPO, MTP […]

Data Center

USD100B sales of 800G and 1.6Tbps Switch in the next 5 years

Dell’Oro Group released a report about Ethernet Data Center Switch recently, Ethernet Switch – Data Center 5-Year Forecast Report. Based on the report, the group mentions that Front-end Networks Will Account for More than $100B in Data Center Switch Sales Over the Next Five Years. During the next 5 years to 2028, about 100M shipments […]

Data Center

What is LPO (Linear-drive Pluggable Optics)?

LPO is short for Linear Pluggable Optics (or Linear-drive Pluggable Optics), it is a potential technology to satisfy the low power consumption and high bandwidth demand of data centers like CPO (Co-packaged Optics). Currently, IPEC (The International Photonics & Electronics Committee) is focusing on cutting-edge optoelectronic technologies. Image source from LightCounting The following are the […]

Data Center

Q&A for 200G Transceivers and Cables

Q1: What is the difference among the terms “QSFP56”, “QSFP200”, “200G QSFP” and “200G QSFP56”? A1: They all refer to the same transceiver type. The electrical data path interface of a 200G QSFP consists of 4 lanes, with each lane transmitting 50Gbit/s data. Each lane of a 200G QSFP is designed to handle up to […]

Data Center

Q&A for 100G SFP-DD and 100G DSFP Systems

Q1: What are the SFP-DD and DSFP form factors? A1: The SFP-DD is short for Small Form-factor Pluggable – Double-Density and SFP-DD form-factor is defined by the SFP-DD MSA, while the DSFP is short for Dual Small Form-factor Pluggable and is defined by the DSFP MSA. They are a compact SFP-like form factor with 2x […]

Data Center