4-Rule for using Standard MPO Patch Cord, MPO Connector and MPO Adaptor

Rule-1: When mating two MPO patch cords, it shall be an MPO male connector and an MPO female connector. Rule-2: For the standard MPO Connectors, changing the polarity, or adding or removing the guiding pins in the field is not allowed. Rule-3: MPO Female connector for direct connection to the optical module if it is […]

Data Center

SWDM advantages for duplex MMF connectivity in modern data center

SWDM is short for Short Wavelength Division Multiplexing. it offers users an alternate solution for 40Gbps, 100Gbps, and higher connectivity over duplex multimode fiber. Some of the many advantages of SWDM are: Reach – up to 440m for 40G and 150m for 100G 40G SWDM can operate link distance up to 240, 350, and 440 […]

Data Center

Which 40G MMF duplex transceiver should I choose, QSFP-40G-SRBD or QSFP-40G-SWDM4?

TARLUZ currently offers two 40G transceivers that operate over duplex multimode fiber, QSFP-40G-SWDM4, and QSFP-40G-SRBD transceivers. Both transceivers operate at multimode fiber and are widely deployed in the industry. QSFP-40G-SWDM4 and QSFP-40G-SRBD are using different technology, so they are not able to use each other. QSFP-40G-SWDM4 Transceiver TARLUZ 40G QSFP+ SWDM4 transceiver provides 40Gbps bandwidth […]

Data Center

Introduction to the media used in the next generation Central Office

Cabling is important in the data center/central office. there are two main media used inside the stat center, copper and fiber, the following tables are information on copper and fiber used inside the data center, selecting the right media for the current application and future upgrade is important. Copper Category ISO Channel Class Maximum Bandwidth […]

Data Center

What you should know about DSFP.

D’SDSFP Dual Small Form-Factor Pluggable DSFP MSA is developing a SFP+/SFP28 compatible form factor for 5G Mobile applications DSFP has two TX/RX high speed pin pairs, instead of one TX/RX pin pair in SFP+/SFP28 DSFP is mechanically the same as SFP+/SFP28 modules DSFP host ports accept SFP+/SFP28 modules Some SFP+/SFP28 hardware control and alarm pins […]

Data Center

Introduction to 100G Single Lambda Transceivers

Introduction 100G Single Lambda transceivers were defined by 100G Lambda MSA (100G Lambda Multi-Source Agreement). The MSA 100G MSA uses 100G PAM4 optical signaling and encoding it is able to use 100Gb/s per channel to transmit from 2m up to 40KM via single-mode fiber. Advantages The traditional 100Gb/s optical standards such as 100GBASE LR4, 100GBASE […]

400G Network, Data Center

Introduction to transceivers used in the data center

The pluggable Transceivers is one of the main network components in the modern data center, based on the data rate structured cabling topology, different form factors transceivers like SFP, SFP+, XFP, QSFP+ SFP28, SFP56, CFP, CFP2, CFP4, QSFP28, QSFP56, QSFP-DD may be used. The flowing list is about how to choose transceivers intra racks, inter […]

Data Center

Introduction to QSFP-DD800 and QSFP112

The Quad Small Form Factor Pluggable Double Density (QSFPDD) Multi-Source Agreement (MSA) group announces the release of a hardware specification revision 7.0 for updating QSFP-DD, The main topic is introducing QSFP-DD800 and QSFP112 form factor. QSFP-DD is the premier 8-lane data center pluggable module form factor. This QSFP-DD optical module designed backward compatible with existing […]