Passive Component

IEC Connector Loss Grades Introduction

Insertion Loss get grades of A, B, C, etc. Table 2 – Single Mode attenuation grades at 1310nm and 1550nm (dB) Attenuation grade Attenuation (≥ 97%)a Mean Notes A Reserved for future application B ≤ 0.25 ≤ 0.12 C ≤ 0.50 ≤ 0.25 D ≤ 1.0 ≤ 0.50 The probability of a random mated connector […]

Passive Component

Tipos de conectores de acuerdo al “Ferrule”

P. ¿Cuáles son los tipos de conect- ores de acuerdo a su punta (ferrule)? R. La terminación estándar es la PC (Physical Contac) que es ligeramente convexa, esta forma busca que la su- perficie de contacto entre dos conect- ores se restringa al área central, es de- cir donde se ubican los vidrios. El otro […]

Passive Component

LICHTWELLENLEITER – STECKER UND KUPPLUNGEN

Steckverbinder: E2000 Stecker mit Verriegelung und Schutzkappe, die beim Einstecken in eine Kupplung weggeklappt wird. Für Anwendungen, wo hohe Präzision gefor- dert ist, Multimode und Singlemode, auch oft mit APC-Schliff. Erhältlich konfektioniert auf Pigtails, Patch- und Breakout-Kabel, sowie Kupplung. Steckverbinder: FC Stecker mit Überwurfmutter, wird mit der Kupplung verschraubt. Häufig bei Telekom-Anwendungen, Multimode und Singlemode. […]

Passive Component

Złącza światłowodowe

FC/PC Złącza FC zostały specjalnie zaprojektowane z myślą o aplikacjach telekomunikacyjnych wymagających stałego i pewnego połączenia. Skręcane, gwintowane zakończenie zapewnia niezawodność połączeń nawet w przypadku częstych przełączeń. Zastosowana w złączu ferrula typu PC (z kontaktem fizycznym bez przerwy powietrznej) zmniejsza odbicie wsteczne. Ferrule wykonywane są z dwutlenku cyrkonu lub stopów nierdzewnej stali. Właściwości: Gwintowany sposób […]

Passive Component

Les principaux connecteurs

Le connecteur Le connecteur SC est le plus employé actuellement. On le retrouve sur un grand nombre d'équipements actifs quelle que soit l'application (Ethernet, Fiberchannel...). Il présente de nombreux avantages par rapport aux connecteurs ST : dépassement moindre de l'embout donc pas de risque de pollution, conception "pull-proof" donc pas de risque de déconnexion lors [...]
Passive Component

A colorful Data Center

Color provides quick visual identification. Color coding simplifies management and can save you hours when you need to trace cables. Color coding can be applied to ports on a patch panel: patch panels themselves come with different color jacks or have colored inserts that surround the jack. Cables are available in many colors (the color […]

Data Center, Passive Component

ST Connector Introduction – Fiber Connector Introduction

The ST connector (Straight Tip or Bayonet Fiber Optic Connector ), mainly applied in Multimode, rarely single-mode, complied with IEC 61754-2, the ST Connector features a 2.5 mm ferrule with a quick release bayonet (stick and twist) style body for ease of use. ST connectors are available for single mode UPC with yellow boots, APC […]

Passive Component

FC Connector Introduction – Fiber Connector Introduction

The FC connector (short for Ferrule Connector or Fiber Channel), it mainly applied for Datacom, telecom, measurement equipment, single-mode lasers; becoming less common, The FC connector features a 2.5 mm ferrule and a threaded metal coupling nut, for a secure connection in high vibration environments and in laboratory testing for consistent results. A range of […]

Passive Component

LC Connector Introduction – Fiber Connector Introduction

The LC connector (short for Lucent Connector, Little Connector, or Local Connector), It features a 1.25mm Zirconia ferrule in a small form factor (SFF) fibre optic connector housing with a snag free latch which gives an audible click upon engaging for reliable and high density connections. The LC connector complied with IEC 61754-20, it is […]

Passive Component